翻訳と辞書
Words near each other
・ 5th Battalion Bombay Sepoys
・ 5th Battalion of the 14th Central Bosnian Brigade
・ 5th Battalion, 4 Gorkha Rifles
・ 5th Battalion, Canadian Mounted Rifles, CEF
・ 5th Battalion, Royal Australian Regiment
・ 5th Battalion, Ulster Defence Regiment
・ 5th Battle Squadron (United Kingdom)
・ 5th Bavarian Reserve Division
・ 5th Bengal European Cavalry
・ 5th Bengal European Regiment
・ 5th Bengal Light Cavalry
・ 5th Berlin International Film Festival
・ 5th Blackshirt Division 1 Febbraio
・ 5th Bodil Awards
・ 5th Bomb Wing
5DX
・ 5E
・ 5EBI
・ 5ESS switch
・ 5F
・ 5F-AB-FUPPYCA
・ 5F-AB-PINACA
・ 5F-ADB
・ 5F-ADB-PINACA
・ 5F-ADBICA
・ 5F-AMB
・ 5F-APINACA
・ 5F-CUMYL-PINACA
・ 5F-EMB-PINACA
・ 5F-NNE1


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

5DX : ウィキペディア英語版
5DX
The 5DX was an automated X-ray inspection robot, which belonged to the set of automated test equipment robots and industrial robots utilizing machine vision. The 5DX was manufactured by Agilent Technologies. The 5DX performed a non-destructive structural test using laminography (tomography) to take 3D slices of an assembled printed circuit board. It was used in the assembled printed circuit board (PCB) electronics manufacturing industry to provide process feedback to a surface mount technology assembly line, as well as defect capture.
The 5DX was one of several tools used by many companies in the electronics manufacturing services sector to provide a means of inspecting both the visible and hidden solder connections between the printed circuit boards and components attached to those printed circuit boards. These solder connections (also known as solder joints) are referred to as PCB interconnects.
==5DX technology==
The 5DX used a gantry robot to move the assembled printed circuit board underneath an source to be able to image the components' joints that require inspection. The positioning of board was guided with the use of Computer Aided Design (CAD) data, which represented the outer layers of a printed circuit board's electrical design.
The 5DX system used classical laminography to create an x-ray image “slice”, or image plane that will be distinct from other image planes on the object to be imaged. A slice will remove obstructions above or below the plane of focus so that only the regions of interest remain.
X-Ray systems that use methods such as laminography ( or the now more commonly used tomography ) are marketed as “3D” x-ray systems. X-Ray systems that do not use these methods an only produce a transmissive shadow image are marketed as “2D” systems.
Classical laminography〔Digital computed Laminography and Tomosynthesis - Functional Principles and Industrial Applications; S. Gondrom, S. Schröpfer, FhG ITFP, Saarbrücken, D; International Symposium on Computerized Tomography for
Industrial Applications and Image Processing in Radiology
March, 15 - 17, 1999 Berlin, Germany
〕 is based on a relative motion of the x-ray source, the detector and the object. The x-ray source and the detector are moved synchronously on circles as shown in the figure.
Due to that correlated motion, the location of the projected images of points within the object moves also. Only points from a particular slice, the so called focal slice, will be always projected at the same location onto the detector and therefore imaged sharply. Object structures above and below the focal slice will move as the rotation occurs. Because of that, they aren't imaged sharply and they will blur to a grey background image.
Rotational laminography requires a complex system to produce the rotating x-ray source, rotate the image detector and maintain synchronization between source and detector.
In addition, the laminography systems require a system to map the surface of the object to be imaged. Product to be imaged is rarely perfectly flat.〔IPC-A-600G, Acceptability of Printed Circuit Boards, Section 2.11 Flatness〕 The 5DX system used a laser mapping system to measure bow and twist so that the effects can be compensated in the imaging process.
In the 5DX system the rotating x-ray source is produced by scanning a high energy electron beam around a x-ray producing target integral to the x-ray tube. The rotating detector is implemented by rotating a x-ray sensitive screen mechanically and projecting the image into a high sensitivity digital camera.
Aside from the electro-mechanical complexity, the main disadvantages of classical laminography are the background intensity that reduces the contrast resolution and the fact that in each measurement only one slice is imaged sharply. All other slices have to be inspected consecutively by displacing the object vertically.
Classical laminography has been replaced by computed tomography (CT) or computed lamingraphy in more modern automated x-ray systems.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「5DX」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.