翻訳と辞書
Words near each other
・ Conductive education
・ Conductive Education School, Kuwait
・ Conductive elastomer
・ Conductive hearing loss
・ Conductive ink
・ Conductive keratoplasty
・ Conductive pedagogy
・ Conductive polymer
・ Conductive textile
・ Conductive wireless charging
・ Conductivity
・ Conductivity (electrolytic)
・ Conductivity factor
・ Conductivity near the percolation threshold
・ Conductivity of transparency
Conductometry
・ Conductor
・ Conductor (album)
・ Conductor (class field theory)
・ Conductor (company)
・ Conductor (military appointment)
・ Conductor (rail)
・ Conductor 1492
・ Conductor 786
・ Conductor clashing
・ Conductor gallop
・ Conductor marking lights
・ Conductor of an abelian variety
・ Conductor of an elliptic curve
・ Conductor pipe


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Conductometry : ウィキペディア英語版
Conductometry

Conductometry is a measurement of electrolytic conductivity to monitor a progress of chemical reaction. Conductometry has notable application in analytical chemistry, where conductometric titration is a standard technique. In usual analytical chemistry practice, the term ''conductometry'' is used as a synonym of ''conductometric titration'', while the term conductimetry is used to describe non-titrative applications.〔Khopkar, S.M., "Basic Concepts of Analytical Chemistry", 3rd edition, 2007, ISBN 978-81-224-2092-0.〕
== Conductometric titration ==
Conductometric titration is a type of titration in which the electrolytic conductivity of the reaction mixture is continuously monitored as one reactant is added. The equivalence point is the point at which the conductivity undergoes a sudden change. Marked increases or decrease in conductance are associated with the changing concentrations of the two most highly conducting ions—the hydrogen and hydroxyl ions.〔Katz et al., 1984 S. Katz, R.P. Beatson and A.M. Scallan, The determination of strong and weak acidic groups in sulfite pulps, Svensk Paperstidn. 6 (1984), pp. 48–53.〕 The method can be used for titrating coloured solutions or homogeneous suspension (e.g.: wood pulp suspension〔), which cannot be used with normal indicators.
Acid-base titrations and redox titrations are often performed in which common indicators are used to locate the end point e.g., methyl orange, phenolphthalein for acid base titrations and starch solutions for iodometric type redox process. However, electrical conductance measurements can also be used as a tool to locate the end point, e.g., in a titration of a HCl solution with the strong base NaOH.
As the titration progresses, the protons are neutralized to form water by the addition of NaOH. For each amount of NaOH added equivalent amount of hydrogen ions is removed. Effectively, the mobile H+ cation is replaced by the less-mobile Na+ ion, and the conductivity of the titrated solution as well as the measured conductance of the cell fall. This continues until the equivalence point is reached, at which one obtains a solution of sodium chloride, NaCl. If more base is added, an increase in conductivity or conductance is observed, since more ions Na+ and OH are being added and the neutralization reaction no longer removes an appreciable amount of H+. Consequently, in the titration of a strong acid with a strong base, the conductance has a minimum at the equivalence point. This minimum can be used, instead of an indicator dye, to determine the endpoint of the titration. The conductometric titration curve is a plot of the measured conductance or conductivity values as a function of the volume of the NaOH solution added. The titration curve can be used to graphically determine the equivalence point.
For reaction between a weak acid-weak base in the beginning conductivity decreases a bit as the few available H+ ions are used up. Then conductivity increases slightly up to the equivalence point volume, due to contribution of the salt cation and anion.(This contribution in case of a strong acid-strong base is negligible and is not considered there.)After the equivalence point is achieved the conductivity increases rapidly due to the excess OH- ions.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Conductometry」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.