Distortionmeter (or more precisely distortion factor meter) is an electronic measuring instrument which displays the amount of distortion added to the original signal by an electronic circuit. == Harmonic distortion == Harmonic distortion is equivalent to adding harmonics to a signal. When a purely sinusoidal signal is distorted, a series of harmonics is superimposed on the original signal. If the input is : The normalized output is : The Total harmonics distortion (THD) is defined as the ratio of the harmonics to the fundamental; 〔Reference data for Radio Engineers, Howard W.Sams & co.ITT, ISBN 0-672-21218-8, p.18-12〕 i.e., This ratio can be given in dB or in percentage. 抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)』 ■ウィキペディアで「Distortionmeter」の詳細全文を読む スポンサード リンク
|