翻訳と辞書
Words near each other
・ Fieldwork (disambiguation)
・ Fieldwork (novel)
・ Fieldy's Dreams
・ Fielfraz
・ Fieller's theorem
・ Field-reversed configuration
・ Field-sequential color system
・ Field-theoretic simulation
・ Field-tube boiler
・ Fieldale Historic District
・ Fieldale, Virginia
・ Fieldata
・ Fieldbrook Farms
・ Fieldbrook, California
・ Fieldbrook, Virginia
Fieldbus
・ Fieldbus Foundation
・ Fieldcraft
・ FieldCraft (company)
・ Fieldcrest Cannon Classic
・ Fieldcrest, West Virginia
・ Fielded text
・ Fielden
・ Fielden Professor of Pure Mathematics
・ Fielder
・ Fielder (surname)
・ Fielder Cook
・ Fielder House
・ Fielder Jones
・ Fielder railway station


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Fieldbus : ウィキペディア英語版
Fieldbus

Fieldbus is the name of a family of industrial computer network protocols used for real-time distributed control, standardized as IEC 61158.
A complex automated industrial system — such as manufacturing assembly line — usually needs a distributed control system—an organized hierarchy of controller systems—to function. In this hierarchy, there is usually a Human Machine Interface (HMI) at the top, where an operator can monitor or operate the system. This is typically linked to a middle layer of programmable logic controllers (PLC) via a non-time-critical communications system (e.g. Ethernet). At the bottom of the control chain is the fieldbus that links the PLCs to the components that actually do the work, such as sensors, actuators, electric motors, console lights, switches, valves and contactors.
== Description ==
Fieldbus is an industrial network system for real-time distributed control. It is a way to connect instruments in a manufacturing plant. Fieldbus works on a network structure which typically allows daisy-chain, star, ring, branch, and tree network topologies. Previously, computers were connected using RS-232 (serial connections) by which only two devices could communicate. This would be the equivalent of the currently used 4-20 mA communication scheme which requires that each device has its own communication point at the controller level, while the fieldbus is the equivalent of the current LAN-type connections, which require only one communication point at the controller level and allow multiple (hundreds) of analog and digital points to be connected at the same time. This reduces both the length of the cable required and the number of cables required. Furthermore, since devices that communicate through fieldbus require a microprocessor, multiple points are typically provided by the same device. Some fieldbus devices now support control schemes such as PID control on the device side instead of forcing the controller to do the processing.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Fieldbus」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.