In telecommunication, a non-return-to-zero (NRZ) line code is a binary code in which ones are represented by one significant condition, usually a positive voltage, while zeros are represented by some other significant condition, usually a negative voltage, with no other neutral or rest condition. The pulses in NRZ have more energy than a return-to-zero (RZ) code, which also has an additional rest state beside the conditions for ones and zeros. NRZ is not inherently a self-clocking signal, so some additional synchronization technique must be used for avoiding bit slips; examples of such techniques are a run length limited constraint and a parallel synchronization signal. For a given data signaling rate, i.e., bit rate, the NRZ code requires only half the baseband bandwidth required by the Manchester code (the passband bandwidth is the same). When used to represent data in an asynchronous communication scheme, the absence of a neutral state requires other mechanisms for bit synchronization when a separate clock signal is not available. NRZ-Level itself is not a synchronous system but rather an encoding that can be used in either a synchronous or asynchronous transmission environment, that is, with or without an explicit clock signal involved. Because of this, it is not strictly necessary to discuss how the NRZ-Level encoding acts "on a clock edge" or "during a clock cycle" since all transitions happen in the given amount of time representing the actual or implied integral clock cycle. The real question is that of sampling—the high or low state will be received correctly provided the transmission line has stabilized for that bit when the physical line level is sampled at the receiving end. However, it is helpful to see NRZ transitions as happening on the trailing (falling) clock edge in order to compare NRZ-Level to other encoding methods, such as the mentioned Manchester code, which requires clock edge information (is the XOR of the clock and NRZ, actually) see the difference between NRZ-Mark and NRZ-Inverted. ==Unipolar non-return-to-zero level== (詳細はDC bias on the transmission line (conventionally positive), while "zero" is represented by the absence of bias - the line at 0 volts or grounded. For this reason it is also known as "on-off keying." In clock language, a "one" transitions to or remains at a biased level on the trailing clock edge of the previous bit, while "zero" transitions to or remains at no bias on the trailing clock edge of the previous bit. Among the disadvantages of unipolar NRZ is that it allows for long series without change, which makes synchronization difficult - although this is not unique to the unipolar case. One solution is to not send bytes without transitions. More critically, and unique to unipolar NRZ, are issues related to the presence of a transmitted DC level - the power spectrum of the transmitted signal does not approach zero at zero frequency. This leads to two significant problems - first, the transmitted DC power leads to higher power losses than other encodings and second, the presence of a DC signal component requires that the transmission line be DC coupled. 抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)』 ■ウィキペディアで「Non-return-to-zero」の詳細全文を読む スポンサード リンク
|